Rapid Temperature Change Chamber

Rapid Temperature Change Chamber

The Rapid Temperature Change Chamber simulates extreme and drastic temperature fluctuations to comprehensively evaluate the structural stability and electrical reliability of products under thermal stress. By precisely executing high-speed temperature cycling, it accelerates the exposure of potential process defects, providing reliable data support for early failure analysis and quality control.


Key Specifications

  • Temperature Range: Configurable per model and test requirements.

  • Chamber Volume: Multiple sizes for different samples and capacities.

  • Controller: User-friendly system for stable and precise operation.

  • Power Supply: Standard or customized to local electrical standards.

WhatsApp Now
WHAT ARE YOU LOOKING FOR?
*
This field is required
Total quantity you need
*
This field is required
*
This field is required
Email format error
Due to email instability, you might miss our correspondence. Please provide your phone number for alternative contact.
This field is required
Telephone information is wrong!
Send Message
  • Product Details
  • Technical Specifications
  • Key Advantages
  • Applications
  • FAQs

Product Details

测试孔

Test port

控制面板

Control panel

密封结构(双胶圈)

Sealing structure (dual O-rings)

内部风道

Internal airflow duct

内部结构图2

Internal structure diagram

样品架(搁架)

Sample rack (shelf)


Technical Specifications

Rapid Temperature Change Chamber
Performance IndexInner Chamber Size D×W×HCustomized according to specimen size and quantity
Temperature RangeA: -20℃~150℃ B: -40℃~150℃ C: -60℃~150℃ D: -70℃~150℃
Humidity Range30%~98%RH (40~90℃), controllable and adjustable
Temperature Fluctuation≤±0.5℃
Temperature Uniformity≤±2℃
Humidity Deviation+2, -3%RH
Temperature Ramp Rate1.0~3.4℃/min linearly adjustable; Standard rapid temperature change range: 1.0~15℃/min linearly adjustable
Timer Range0~9999H adjustable
Temperature & Humidity Operation Control SystemControllerImported 7-inch LED programmable touch screen with Chinese dialogue display, microcomputer integrated controller, equipped with RS232/485 remote communication
Precision ParameterTemperature setting & indication precision ±0.1℃, resolution ±0.1℃
Temperature SensorPlatinum Resistance PT100Ω/MV
Refrigeration SystemFully hermetic French Tecumseh or German Bitzer compressor, dual-stage cascade refrigeration
Heating SystemFar-infrared nickel alloy high-speed electric heater (3KW × 3)
Humidifying SystemExternal boiler steam humidifier
Construction MaterialsChamber MaterialOuter cabinet: galvanized steel plate with phosphating electrostatic plastic spraying; Inner tank: SUS stainless steel mirror plate
Thermal Insulation MaterialHigh-density glass fiber cotton, insulation thickness 100mm
Air Circulation Mixing SystemLong-shaft fan motor, high & low temperature resistant multi-blade impeller, forced vertical convection circulation

Product Features

  • Safety1.png

    Stable Performance

    The equipment is designed for dependable operation and repeatable testing performance.
  • Temperature-Control.png

    Accurate Temperature / Humidity Control

    The control system helps maintain stable testing conditions for more accurate verification.
  • Durable-Structure.png

    Durable Structure

    The chamber structure is designed for long-term use in laboratory and industrial environments.
  • Easy-Operation.png

    Easy Operation

    User-friendly control and accessible design make daily operation and maintenance easier.

Configuration Options

Standard Configuration
  • Standard Controller:

    Standard configuration includes a practical controller for daily testing operation.

  • Standard Observation Window:

    Observation window is available on selected models for convenient monitoring.

  • Standard Test Port:

    Test port can be included for cable routing or sample monitoring when required.

Optional Configuration
  • Data Logger:

    Optional data logging is available for test data recording and management.

  • Communication Port:

    Communication interface can be added for data transfer or remote integration.

  • Special Material:

    Special chamber material can be selected based on test media or corrosion requirements.

  • Customized Size:

    Chamber dimensions can be customized for different sample sizes and capacities.

Applications

行业应用-电子电气.jpg

Electronics & ElectricalSuitable for performance and reliability testing of electronic and electrical products.

行业应用-金属五金.jpg

Metal & Surface TreatmentApplicable to corrosion resistance, durability, or aging evaluation of metal parts and coatings.

行业应用-汽车.jpg

AutomotiveUsed for environmental durability and quality verification of automotive components.

行业应用-塑料与橡胶.jpg

Plastics & RubberHelps evaluate the stability and environmental resistance of plastic and rubber materials.

行业应用-实验室.jpg

Laboratory TestingWidely used in laboratories for research validation, quality control, and test development.


FAQs- Rapid Temperature Change Chamber

Q
What is the difference between a rapid temperature change test chamber and a standard high/low-temperature test chamber?
A
Standard high/low-temperature test chambers typically have temperature ramp rates of 1°C to 3°C/min, whereas rapid temperature change test chambers are designed for high-load, large-temperature-differential stress testing, achieving ramp rates of 5°C to 15°C/min. They simulate extreme temperature environments more rigorously and rapidly, helping to accelerate the exposure of latent manufacturing or material defects in products.
Q
How often should the equipment's air filter and condenser be cleaned?
A
It is recommended to clean the air filter regularly—either weekly or monthly—using a vacuum cleaner or compressed air to remove dust and prevent blockages that could impair airflow and temperature ramp rates. The condenser should be cleaned at least once a month using a soft brush or compressed air (working from top to bottom) to ensure efficient heat dissipation and prevent system shutdowns caused by high-temperature overload.
Q
How should the equipment be maintained if it is to be taken out of service for an extended period?
A
Before long-term storage, drain any residual liquid from the water tank and piping, wipe the interior of the chamber clean, and apply anti-rust oil. Then, disconnect the power supply, cover the unit with a dust cover, and store it in a dry, well-ventilated area. To prevent component deterioration due to moisture, it is recommended to power on the unit and run it without a load once a month.

Request Your Custom Quote – Get Started Today

We are your one-stop supplier of environmental test equipment with 20+ years of technical experience. Fill in the form, our engineers will send customized quotes and technical data within 24 hours.

Get Professional Solution & Free Quotation

We provide high-quality ISO and CE certified environmental test equipment, covering standard models and customized non-standard solutions for automotive, electronics, new energy and aerospace industries. Leave your contact information and requirements, our professional team will reply to you within 24 hours.

WHAT ARE YOU LOOKING FOR?
*
This field is required
Total quantity you need
*
This field is required
*
This field is required
Email format error
Due to email instability, you might miss our correspondence. Please provide your phone number for alternative contact.
This field is required
Telephone information is wrong!
Send Message
Contact

Whatsapp: +86-15312530178

ADD: No. 68, East Yijing Road, Jintan District, Changzhou

bottom_media_icon1
Quick Links

Products

About Us

Resources

Contact

Main Products

Drying Ovens

Temperature & Humidity Chambers

Corrosion Chambers

Weathering Chambers

Special Test Chambers

IP Test Equipment

Walk-in & Customized Equipment

Solutions

Manufacturing QA Solutions

Overseas Distributor Solutions

Get a Custom Quote in 24 Hours
HFWE’s specialists deliver high-quality, cost-effective environmental test solutions for your needs. Send your project details now for a customized proposal!
Company Name
*
This field is required
Email
*
This field is required
Email format error
Phone
This field is required
Telephone information is wrong!
Name
*
This field is required
Message
*
This field is required
Send Message